Transformer Oil Manufacturer

Transformer Oil
Business Type Manufacturer, Exporter, Supplier, Retailer, Wholesaler
Usage Industrial
Flow Smooth
Type Lubricants
Click to view more

Preferred Buyer From

Location Worldwide

Product Details

Application
Transformer
Benefit
Increases life & service life
Resistivity
Corrosion & Chemical resistant

As, we have a well-organized resource chain system, our organization is capable of fulfilling wholesale consignments with ease and make on time deliveries. Courtesy a state-of-the-art warehousing unit and an ultramodern inventory control system, we take care of product storage related work with ease. Our warehouse and system empowers us to maintain year round products' availability.

Yes! I am interested


Technical Data

CHARACTERISTIC TEST METHOD MIN. MAX
Appearence A resprentative sample of the oil shall be examined in 100 mm thick layer at 27 degrree The oil shall be clear, transparenta and free from suspended matter or sediments.
Density@29.5degrreC.G/cm3 IS:1448(P-16)1977 - 0.89
Kinematic Viscosity, cSt@27degrreC IS:1448(P-25)1976 -I 27
Interfacial Tension , N/M@ 27 degrre C IS:6104:1971 0.04  
Flash Point Pensky-Marten (closed) degree C IS:1448(P-21)1992 140  
Pour Point, degreeC IS:1448(P-10)1970   -6
Netralisation Value IS:14489(P-2)1967 NIL 0.03
a) Total Acidity , mgKOH/gm b)Inorganic Acidity/Alkalinity   No-corrosive Non-corrosive
Corrrosive Sulphur Copper Strip,19hrs@140degreeC ANNEX- B    
Electric Strength (BDV), KV,r IS:6792:1992    
a)New Unfiltered Oil   30  
b)After Filteration.   60  
Dielectric Dissipation Factor IS:6262:1971 -I 0
(Tan Delta ) @90degreeC      
Specific Resistance (Resistivity) Ohm-cm IS:6103:1971 1500*10 ^12  
a)At 27degree C   35*10 ^12  
b)at 90degree C.      
Oxidation Stability (after oxidation for 164hrs @100degree C ANNEX-C 1500*10^12 0.4
a)Neutralisation Value , mgKOH/gm   35*10^12 0.1
b)Total Acidity, wt%      
Acclerated Ageing Test(open Baker Method with Copper Catalyst) IS:12177:1987    
96hrs @115degree C Method A 2.5*10^12 0.2
a)Specific RESISTANCE , Resistivity Ohm-cm @ 90degree C IS:6103:1971 0.2*10^12 0.05
b)Specific Resistance , Resistivity Ohm-cm @ 90degree C IS:6103:1972    
c)Dielectric Dissipation Factor ( Tan Delta) @90 degree C IS:6103:1973    
d)Total Acidity, mg KOH/GM IS:14489(P-2)1967    
e)Total Sludge Value , wt % ANNEX A of IS:12177 The soil shall contain no antioxidant additive.  
Presence of Oxidation Inhibitor IS:13631:1992    
Water Content, ppm IS:13567:1992 50  

Looking for "Transformer Oil" ?

Explore More Products



Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us